Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38649588

RESUMO

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

2.
Eur Heart J Digit Health ; 5(1): 50-59, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38264702

RESUMO

Aims: Implantable cardioverter defibrillator (ICD) therapies have been associated with increased mortality and should be minimized when safe to do so. We hypothesized that machine learning-derived ventricular tachycardia (VT) cycle length (CL) variability metrics could be used to discriminate between sustained and spontaneously terminating VT. Methods and results: In this single-centre retrospective study, we analysed data from 69 VT episodes stored on ICDs from 27 patients (36 spontaneously terminating VT, 33 sustained VT). Several VT CL parameters including heart rate variability metrics were calculated. Additionally, a first order auto-regression model was fitted using the first 10 CLs. Using features derived from the first 10 CLs, a random forest classifier was used to predict VT termination. Sustained VT episodes had more stable CLs. Using data from the first 10 CLs only, there was greater CL variability in the spontaneously terminating episodes (mean of standard deviation of first 10 CLs: 20.1 ± 8.9 vs. 11.5 ± 7.8 ms, P < 0.0001). The auto-regression coefficient was significantly greater in spontaneously terminating episodes (mean auto-regression coefficient 0.39 ± 0.32 vs. 0.14 ± 0.39, P < 0.005). A random forest classifier with six features yielded an accuracy of 0.77 (95% confidence interval 0.67 to 0.87) for prediction of VT termination. Conclusion: Ventricular tachycardia CL variability and instability are associated with spontaneously terminating VT and can be used to predict spontaneous VT termination. Given the harmful effects of unnecessary ICD shocks, this machine learning model could be incorporated into ICD algorithms to defer therapies for episodes of VT that are likely to self-terminate.

3.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37815462

RESUMO

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodos
4.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
5.
J Am Heart Assoc ; 12(8): e028661, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37042261

RESUMO

Background Idiopathic ventricular fibrillation (VF) is a diagnosis of exclusion following normal cardiac investigations. We sought to determine if exercise-induced changes in electrical substrate could distinguish patient groups with various ventricular arrhythmic pathophysiological conditions and identify patients susceptible to VF. Methods and Results Computed tomography and exercise testing in patients wearing a 252-electrode vest were combined to determine ventricular conduction stability between rest and peak exercise, as previously described. Using ventricular conduction stability, conduction heterogeneity in idiopathic VF survivors (n=14) was compared with those surviving VF during acute ischemia with preserved ventricular function following full revascularization (n=10), patients with benign ventricular ectopy (n=11), and patients with normal hearts, no arrhythmic history, and negative Ajmaline challenge during Brugada family screening (Brugada syndrome relatives; n=11). Activation patterns in normal subjects (Brugada syndrome relatives) are preserved following exercise, with mean ventricular conduction stability of 99.2±0.9%. Increased heterogeneity of activation occurred in the idiopathic VF survivors (ventricular conduction stability: 96.9±2.3%) compared with the other groups combined (versus 98.8±1.6%; P=0.001). All groups demonstrated periodic variation in activation heterogeneity (frequency, 0.3-1 Hz), but magnitude was greater in idiopathic VF survivors than Brugada syndrome relatives or patients with ventricular ectopy (7.6±4.1%, 2.9±2.9%, and 2.8±1.2%, respectively). The cause of this periodicity is unknown and was not replicable by introducing exercise-induced noise at comparable frequencies. Conclusions In normal subjects, ventricular activation patterns change little with exercise. In contrast, patients with susceptibility to VF experience activation heterogeneity following exercise that requires further investigation as a testable manifestation of underlying myocardial abnormalities otherwise silent during routine testing.


Assuntos
Síndrome de Brugada , Complexos Ventriculares Prematuros , Humanos , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Sistema de Condução Cardíaco , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/complicações , Eletrocardiografia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Sobreviventes
6.
Cardiovasc Digit Health J ; 4(2): 60-67, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37101944

RESUMO

Background: Accurately determining arrhythmia mechanism from a 12-lead electrocardiogram (ECG) of supraventricular tachycardia can be challenging. We hypothesized a convolutional neural network (CNN) can be trained to classify atrioventricular re-entrant tachycardia (AVRT) vs atrioventricular nodal re-entrant tachycardia (AVNRT) from the 12-lead ECG, when using findings from the invasive electrophysiology (EP) study as the gold standard. Methods: We trained a CNN on data from 124 patients undergoing EP studies with a final diagnosis of AVRT or AVNRT. A total of 4962 5-second 12-lead ECG segments were used for training. Each case was labeled AVRT or AVNRT based on the findings of the EP study. The model performance was evaluated against a hold-out test set of 31 patients and compared to an existing manual algorithm. Results: The model had an accuracy of 77.4% in distinguishing between AVRT and AVNRT. The area under the receiver operating characteristic curve was 0.80. In comparison, the existing manual algorithm achieved an accuracy of 67.7% on the same test set. Saliency mapping demonstrated the network used the expected sections of the ECGs for diagnoses; these were the QRS complexes that may contain retrograde P waves. Conclusion: We describe the first neural network trained to differentiate AVRT from AVNRT. Accurate diagnosis of arrhythmia mechanism from a 12-lead ECG could aid preprocedural counseling, consent, and procedure planning. The current accuracy from our neural network is modest but may be improved with a larger training dataset.

7.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734205

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodos
8.
Eur Heart J Case Rep ; 7(2): ytad016, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36819886

RESUMO

Background: Guidelines support upgrade to cardiac resynchronization therapy (CRT) through His-bundle pacing (HBP) in pacing-induced cardiomyopathy and moderate left ventricular systolic dysfunction (LVSD). Lead-related venous occlusion can represent an obstacle to upgrade procedures. We describe a technique to overcome venous occlusion through direct puncture of a collateral vein facilitating upgrade to HBP. Case summary: An 84-year-old man with a right ventricular (RV) pacemaker was referred with New York Heart Association (NYHA) Class III breathlessness secondary to moderate LVSD (left ventricular ejection fraction [LVEF] 45%). Device interrogation revealed 100% RV pacing and AV-dyssynchrony. To optimize atrioventricular (AV) and interventricular (VV) synchrony a CRT upgrade with HBP was planned. Venography revealed an occluded left subclavian vein which was probed in a retrograde manner using a 6F MPA catheter from right femoral venous access. We were able to direct the catheter distal to the left brachio-cephalic vein and define the occlusion using contrast. A collateral branch was identified, a J-wire was left in this branch and venous access was secured at this medial subclavian site using the Seldinger technique. A right atrial lead was deployed and 69 cm ISI-1 His lead was deployed via a C315 sheath at the His-bundle. The resulted in non-selective HBP (Stim-QRS end 146 ms). There were no procedural complications. Two months later both symptoms and LV function (LVEF 55%) improved. Discussion: Lead-related venous occlusion occurs frequently and can be probed in a retrograde manner from femoral venous access using contrast, facilitating direct percutaneous puncture of collateral venous branches to allow upgrade to CRT via HBP.

9.
Eur Heart J Digit Health ; 3(3): 405-414, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36712163

RESUMO

Aims: Accurately determining atrial arrhythmia mechanisms from a 12-lead electrocardiogram (ECG) can be challenging. Given the high success rate of cavotricuspid isthmus (CTI) ablation, identification of CTI-dependent typical atrial flutter (AFL) is important for treatment decisions and procedure planning. We sought to train a convolutional neural network (CNN) to classify CTI-dependent AFL vs. non-CTI dependent atrial tachycardia (AT), using data from the invasive electrophysiology (EP) study as the gold standard. Methods and results: We trained a CNN on data from 231 patients undergoing EP studies for atrial tachyarrhythmia. A total of 13 500 five-second 12-lead ECG segments were used for training. Each case was labelled CTI-dependent AFL or non-CTI-dependent AT based on the findings of the EP study. The model performance was evaluated against a test set of 57 patients. A survey of electrophysiologists in Europe was undertaken on the same 57 ECGs. The model had an accuracy of 86% (95% CI 0.77-0.95) compared to median expert electrophysiologist accuracy of 79% (range 70-84%). In the two thirds of test set cases (38/57) where both the model and electrophysiologist consensus were in agreement, the prediction accuracy was 100%. Saliency mapping demonstrated atrial activation was the most important segment of the ECG for determining model output. Conclusion: We describe the first CNN trained to differentiate CTI-dependent AFL from other AT using the ECG. Our model matched and complemented expert electrophysiologist performance. Automated artificial intelligence-enhanced ECG analysis could help guide treatment decisions and plan ablation procedures for patients with organized atrial arrhythmias.

10.
Cardiovasc Eng Technol ; 13(2): 219-233, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34453278

RESUMO

PURPOSE: Left atrial (LA) rapid AF activity has been shown to co-localise with areas of successful atrial fibrillation termination by catheter ablation. We describe a technique that identifies rapid and regular activity. METHODS: Eight-second AF electrograms were recorded from LA regions during ablation for psAF. Local activation was annotated manually on bipolar signals and where these were of poor quality, we inspected unipolar signals. Dominant cycle length (DCL) was calculated from annotation pairs representing a single activation interval, using a probability density function (PDF) with kernel density estimation. Cumulative annotation duration compared to total segment length defined electrogram quality. DCL results were compared to dominant frequency (DF) and averaging. RESULTS: In total 507 8 s AF segments were analysed from 7 patients. Spearman's correlation coefficient was 0.758 between independent annotators (P < 0.001), 0.837-0.94 between 8 s and ≥ 4 s segments (P < 0.001), 0.541 between DCL and DF (P < 0.001), and 0.79 between DCL and averaging (P < 0.001). Poorer segment organization gave greater errors between DCL and DF. CONCLUSION: DCL identifies rapid atrial activity that may represent psAF drivers. This study uses DCL as a tool to evaluate the dynamic, patient specific properties of psAF by identifying rapid and regular activity. If automated, this technique could rapidly identify areas for ablation in psAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Análise Espacial
11.
Heart Rhythm O2 ; 2(5): 439-445, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667958

RESUMO

BACKGROUND: His bundle pacing (HBP) can be achieved in 2 ways: selective HBP (S-HBP), where the His bundle is captured alone, and nonselective HBP (NS-HBP), where local myocardium is also captured, resulting a pre-excited electrocardiogram appearance. OBJECTIVE: We assessed the impact of this ventricular pre-excitation on left and right ventricular dyssynchrony. METHODS: We recruited patients who displayed both S-HBP and NS-HBP. We performed noninvasive epicardial electrical mapping for left and right ventricular activation time (LVAT and RVAT) and pattern. RESULTS: Twenty patients were recruited. In the primary analysis, the mean within-patient change in LVAT from S-HBP to NS-HBP was -5.5 ms (95% confidence interval: -0.6 to -10.4, noninferiority P < .0001). NS-HBP did not prolong RVAT (4.3 ms, -4.0 to 12.8, P = .296) but did prolong QRS duration (QRSd, 22.1 ms, 11.8 to 32.4, P = .0003). In patients with narrow intrinsic QRS (n = 6), NS-HBP preserved LVAT (-2.9 ms, -9.7 to 4.0, P = .331) but prolonged QRS duration (31.4 ms, 22.0 to 40.7, P = .0003) and mean RVAT (16.8 ms, -5.3 to 38.9, P = .108) compared to S-HBP. Activation pattern of the left ventricular surface was unchanged between S-HBP and NS-HBP, but NS-HBP produced early basal right ventricular activation that was not seen in S-HBP. CONCLUSION: Compared to S-HBP, local myocardial capture during NS-HBP produces pre-excitation of the basal right ventricle resulting in QRS duration prolongation. However, NS-HBP preserves the left ventricular activation time and pattern of S-HBP. Left ventricular dyssynchrony is not an important factor when choosing between S-HBP and NS-HBP in most patients.

12.
Am J Cardiol ; 160: 53-59, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34610873

RESUMO

A multivariate risk score model was proposed by Sieira et al in 2017 for sudden death in Brugada syndrome; their validation in 150 patients was highly encouraging, with a C-index of 0.81; however, this score is yet to be validated by an independent group. A total of 192 records of patients with Brugada syndrome were collected from 2 centers in the United Kingdom and retrospectively scored according to a score model by Sieira et al. Data were compiled summatively over follow-up to mimic regular risk re-evaluation as per current guidelines. Sudden cardiac death survivor data were considered perievent to ascertain the utility of the score before cardiac arrest. Scores were compared with actual outcomes. Sensitivity in our cohort was 22.7%, specificity was 57.6%, and C-index was 0.58. In conclusion, up to 75% of cardiac arrest survivors in this cohort would not have been offered a defibrillator if evaluated before their event. This casts doubt on the utility of the score model for primary prevention of sudden death. Inherent issues with modern risk scoring strategies decrease the likelihood of success even in robustly designed tools such as the Sieira score model.


Assuntos
Síndrome de Brugada/terapia , Morte Súbita Cardíaca/epidemiologia , Síndrome de Brugada/complicações , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco , Síndrome do Nó Sinusal/fisiopatologia , Síncope/fisiopatologia , Reino Unido/epidemiologia
14.
Europace ; 23(2): 305-312, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33083839

RESUMO

AIMS: Rate adaptation of the action potential ensures spatial heterogeneities in conduction across the myocardium are minimized at different heart rates providing a protective mechanism against ventricular fibrillation (VF) and sudden cardiac death (SCD), which can be quantified by the ventricular conduction stability (V-CoS) test previously described. We tested the hypothesis that patients with a history of aborted SCD due to an underlying channelopathy or cardiomyopathy have a reduced capacity to maintain uniform activation following exercise. METHODS AND RESULTS: Sixty individuals, with (n = 28) and without (n = 32) previous aborted-SCD event underwent electro-cardiographic imaging recordings following exercise treadmill test. These included 25 Brugada syndrome, 13 hypertrophic cardiomyopathy, 12 idiopathic VF, and 10 healthy controls. Data were inputted into the V-CoS programme to calculate a V-CoS score that indicate the percentage of ventricle that showed no significant change in ventricular activation, with a lower score indicating the development of greater conduction heterogeneity. The SCD group, compared to those without, had a lower median (interquartile range) V-CoS score at peak exertion [92.8% (89.8-96.3%) vs. 97.3% (94.9-99.1%); P < 0.01] and 2 min into recovery [95.2% (91.1-97.2%) vs. 98.9% (96.9-99.5%); P < 0.01]. No significant difference was observable later into recovery at 5 or 10 min. Using the lowest median V-CoS scores obtained during the entire recovery period post-exertion, SCD survivors had a significantly lower score than those without for each of the different underlying aetiologies. CONCLUSION: Data from this pilot study demonstrate the potential use of this technique in risk stratification for the inherited cardiac conditions.


Assuntos
Morte Súbita Cardíaca , Fibrilação Ventricular , Morte Súbita Cardíaca/etiologia , Coração , Humanos , Projetos Piloto , Fatores de Risco , Sobreviventes , Fibrilação Ventricular/diagnóstico
15.
J Vasc Access ; 22(2): 319-321, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32339060

RESUMO

Jugular Tesio lines (TesioCaths; MedCOMP, Harleysville, PA, USA) are frequently used as permanent vascular accesses in haemodialysis patients. During the insertion procedure, arrhythmias are a relatively common complication, usually related to an excessively advanced catheter tip, without major consequences. We present two cases of life-threatening arrhythmias triggered by the Tesio catheter eccentric high-velocity jet of blood resolved after reposition of the catheter without further episodes, despite both lines being inserted under real-time ultrasound and fluoroscopic guidance. We believe dialysis lines should be checked for tip position even when long-standing to prevent relevant complications due to catheter sliding.


Assuntos
Arritmias Cardíacas/etiologia , Cateterismo Venoso Central/efeitos adversos , Falência Renal Crônica/terapia , Diálise Renal , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Feminino , Humanos , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 32(2): 428-438, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33345379

RESUMO

BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento , Função Ventricular Esquerda
17.
J Cardiovasc Electrophysiol ; 31(11): 2964-2974, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32976636

RESUMO

AIMS: A prolonged PR interval may adversely affect ventricular filling and, therefore, cardiac function. AV delay can be corrected using right ventricular pacing (RVP), but this induces ventricular dyssynchrony, itself harmful. Therefore, in intermittent heart block, pacing avoidance algorithms are often implemented. We tested His-bundle pacing (HBP) as an alternative. METHODS: Outpatients with a long PR interval (>200 ms) and intermittent need for ventricular pacing were recruited. We measured within-patient differences in high-precision hemodynamics between AV-optimized RVP and HBP, as well as a pacing avoidance algorithm (Managed Ventricular Pacing [MVP]). RESULTS: We recruited 18 patients. Mean left ventricular ejection fraction was 44.3 ± 9%. Mean intrinsic PR interval was 266 ± 42 ms and QRS duration was 123 ± 29 ms. RVP lengthened QRS duration (+54 ms, 95% CI 42-67 ms, p < .0001) while HBP delivered a shorter QRS duration than RVP (-56 ms, 95% CI -67 to -46 ms, p < .0001). HBP did not increase QRS duration (-2 ms, 95% CI -8 to 13 ms, p = .6). HBP improved acute systolic blood pressure by mean of 5.0 mmHg (95% CI 2.8-7.1 mmHg, p < .0001) compared to RVP and by 3.5 mmHg (95% CI 1.9-5.0 mmHg, p = .0002) compared to the pacing avoidance algorithm. There was no significant difference in hemodynamics between RVP and ventricular pacing avoidance (p = .055). CONCLUSIONS: HBP provides better acute cardiac function than pacing avoidance algorithms and RVP, in patients with prolonged PR intervals. HBP allows normalization of prolonged AV delays (unlike pacing avoidance) and does not cause ventricular dyssynchrony (unlike RVP). Clinical trials may be justified to assess whether these acute improvements translate into longer term clinical benefits in patients with bradycardia indications for pacing.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Algoritmos , Hemodinâmica , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
18.
Orphanet J Rare Dis ; 15(1): 165, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32600364

RESUMO

Hereditary haemorrhagic telangiectasia (HHT) is a multisystemic vascular dysplasia inherited as an autosomal dominant trait. Approximately 10 % of patients have cerebral vascular malformations, a proportion being cerebral arteriovenous malformations (AVMs) and fistulae that may lead to potentially devastating consequences in case of rupture. On the other hand, detection and treatment related-risks are not negligible, and immediate. While successful treatment can be undertaken in individual cases, current data do not support the treatment of unruptured AVMs, which also present a low risk of bleeding in HHT patients. Screening for these AVMs is therefore controversial.Structured discussions, distinctions of different cerebrovascular abnormalities commonly grouped into an "AVM" bracket, and clear guidance by neurosurgical and neurointerventional radiology colleagues enabled the European Reference Network for Rare Vascular Disorders (VASCERN-HHT) to develop the following agreed Position Statement on cerebral screening:1) First, we emphasise that neurological symptoms suggestive of cerebral AVMs in HHT patients should be investigated as in general neurological and emergency care practice. Similarly, if an AVM is found accidentally, management approaches should rely on expert discussions on a case-by-case basis and individual risk-benefit evaluation of all therapeutic possibilities for a specific lesion.2) The current evidence base does not favour the treatment of unruptured cerebral AVMs, and therefore cannot be used to support widespread screening of asymptomatic HHT patients.3) Individual situations encompass a wide range of personal, cultural and clinical states. In order to enable informed patient choice, and avoid conflicting advice, particularly arising from non-neurovascular interpretations of the evidence base, we suggest that all HHT patients should have the opportunity to discuss knowingly brain screening issues with their healthcare provider.4) Any screening discussions in asymptomatic individuals should be preceded by informed pre-test review of the latest evidence regarding preventative and therapeutic efficacies of any interventions. The possibility of harm due to detection of, or intervention on, a vascular malformation that would not have necessarily caused any consequence in later life should be stated explicitly.We consider this nuanced Position Statement provides a helpful, evidence-based framework for informed discussions between healthcare providers and patients in an emotionally charged area.


Assuntos
Malformações Arteriovenosas Intracranianas , Telangiectasia Hemorrágica Hereditária , Adulto , Encéfalo , Criança , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico , Programas de Rastreamento , Doenças Raras , Telangiectasia Hemorrágica Hereditária/diagnóstico , Telangiectasia Hemorrágica Hereditária/genética
19.
J Am Heart Assoc ; 9(7): e013684, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32212911

RESUMO

Background Patients presenting with atrial fibrillation (AF) often undergo a blood test to measure troponin, but interpretation of the result is impeded by uncertainty about its clinical importance. We investigated the relationship between troponin level, coronary angiography, and all-cause mortality in real-world patients presenting with AF. Methods and Results We used National Institute of Health Research Health Informatics Collaborative data to identify patients admitted between 2010 and 2017 at 5 tertiary centers in the United Kingdom with a primary diagnosis of AF. Peak troponin results were scaled as multiples of the upper limit of normal. A total of 3121 patients were included in the analysis. Over a median follow-up of 1462 (interquartile range, 929-1975) days, there were 586 deaths (18.8%). The adjusted hazard ratio for mortality associated with a positive troponin (value above upper limit of normal) was 1.20 (95% CI, 1.01-1.43; P<0.05). Higher troponin levels were associated with higher risk of mortality, reaching a maximum hazard ratio of 2.6 (95% CI, 1.9-3.4) at ≈250 multiples of the upper limit of normal. There was an exponential relationship between higher troponin levels and increased odds of coronary angiography. The mortality risk was 36% lower in patients undergoing coronary angiography than in those who did not (adjusted hazard ratio, 0.61; 95% CI, 0.42-0.89; P=0.01). Conclusions Increased troponin was associated with increased risk of mortality in patients presenting with AF. The lower hazard ratio in patients undergoing invasive management raises the possibility that the clinical importance of troponin release in AF may be mediated by coronary artery disease, which may be responsive to revascularization.


Assuntos
Fibrilação Atrial/sangue , Doença da Artéria Coronariana/sangue , Troponina/sangue , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Biomarcadores/sangue , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Regulação para Cima
20.
Heart Rhythm ; 16(9): 1357-1367, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31170484

RESUMO

BACKGROUND: Bipolar electrogram voltage during sinus rhythm (VSR) has been used as a surrogate for atrial fibrosis in guiding catheter ablation of persistent atrial fibrillation (AF), but the fixed rate and wavefront characteristics present during sinus rhythm may not accurately reflect underlying functional vulnerabilities responsible for AF maintenance. OBJECTIVE: The purpose of this study was determine whether, given adequate temporal sampling, the spatial distribution of mean AF voltage (VmAF) better correlates with delayed-enhancement magnetic resonance imaging (MRI-DE)-detected atrial fibrosis than VSR. METHODS: AF was mapped (8 seconds) during index ablation for persistent AF (20 patients) using a 20-pole catheter (660 ± 28 points/map). After cardioversion, VSR was mapped (557 ± 326 points/map). Electroanatomic and MRI-DE maps were co-registered in 14 patients. RESULTS: The time course of VmAF was assessed from 1-40 AF cycles (∼8 seconds) at 1113 locations. VmAF stabilized with sampling >4 seconds (mean voltage error 0.05 mV). Paired point analysis of VmAF from segments acquired 30 seconds apart (3667 sites; 15 patients) showed strong correlation (r = 0.95; P <.001). Delayed enhancement (DE) was assessed across the posterior left atrial (LA) wall, occupying 33% ± 13%. VmAF distributions were (median [IQR]) 0.21 [0.14-0.35] mV in DE vs 0.52 [0.34-0.77] mV in non-DE regions. VSR distributions were 1.34 [0.65-2.48] mV in DE vs 2.37 [1.27-3.97] mV in non-DE. VmAF threshold of 0.35 mV yielded sensitivity of 75% and specificity of 79% in detecting MRI-DE compared with 63% and 67%, respectively, for VSR (1.8-mV threshold). CONCLUSION: The correlation between low-voltage and posterior LA MRI-DE is significantly improved when acquired during AF vs sinus rhythm. With adequate sampling, mean AF voltage is a reproducible marker reflecting the functional response to the underlying persistent AF substrate.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração , Imagem Cinética por Ressonância Magnética/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Correlação de Dados , Feminino , Fibrose/complicações , Fibrose/diagnóstico , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...